Common Mistakes when fitting Rotary Unions.
Tuesday 21st October 2025
Above is an example of an installation sheet for one type of Filton Rotary Union, these information sheets are all available on our website, https://www.filtonltd.com/EN/catalogues/
All our joints are pressure tested before despatch and are uniquely identifiable by serial number. Early failure of a joint is usually due to one of the following installation mistakes.
- Hoses which are attached to the unions are too short, this causes undue strain on the union which in turn pulls it out of alignment
- Hoses which are attached to the unions are too long causing unnecessary weight which again causes strain on the union
- Badly fitted hoses ie: incorrect bends, again causing strain
- Fitting solid pipework as opposed to flexible hoses will also cause strain on the union
- Attaching too many fittings to the union eg: valves and/or gauges which will cause weight strain issues
- Too many fittings between the roll and the spindle can cause movement of the union. This in turn can cause the centre tube to foul in the roll, resulting in strain on the bearings and on the flexible hose
- Solidly clamping a union preventing natural movement
If you have any questions or if we can help you with your applications you can contact us either by phone on +44 1926 423191 or emailing us on sales@filtonltd.co.uk or technical@filtonltd.co.uk
Recent Posts
-
Our last despatch date for 2025.⠀⠀
12th Nov 2025
-
Common Mistakes when fitting Rotary Unions.
21st Oct 2025
-
20th Aug 2025
-
21st Jul 2025
-
24th Jun 2025
-
14th May 2025
-
14th Apr 2025
-
11th Feb 2025
-
27th Jan 2025
-
23rd Dec 2024

Español
Deutsch
English
Français
Italiano
Polski
Português
Pусский
Türkçe
中文简体